We design and manufacture semiconductor chips, discrete power devices, and power modules for your products.
We design and manufacture semiconductor chips, discrete power devices, and power modules for your products.

Less Energy

More Efficiency

  • Home
  • Products 
    • IPM by Package
    • IGBT Modules
    • IGBT Discretes
    • IGBT Chips
    • SiC
    • FRD(MUR)
    • Bridge Rectifier
  • Application 
    • Electric Vehicle
    • Home Appliance
    • Renewable Energy
    • Industrial Control
    • Electric Power Supplys
  • Technology 
    • Latest IPM Technology
    • High Voltage (HV) Die Technolog
    • Reliability & Qualification
  • About Us 
    • Our Company
    • Technical Team
    • Custom Solutions
  • Contact Us
  • Blog
  • …  
    • Home
    • Products 
      • IPM by Package
      • IGBT Modules
      • IGBT Discretes
      • IGBT Chips
      • SiC
      • FRD(MUR)
      • Bridge Rectifier
    • Application 
      • Electric Vehicle
      • Home Appliance
      • Renewable Energy
      • Industrial Control
      • Electric Power Supplys
    • Technology 
      • Latest IPM Technology
      • High Voltage (HV) Die Technolog
      • Reliability & Qualification
    • About Us 
      • Our Company
      • Technical Team
      • Custom Solutions
    • Contact Us
    • Blog
Free Sample
We design and manufacture semiconductor chips, discrete power devices, and power modules for your products.
We design and manufacture semiconductor chips, discrete power devices, and power modules for your products.

Less Energy

More Efficiency

  • Home
  • Products 
    • IPM by Package
    • IGBT Modules
    • IGBT Discretes
    • IGBT Chips
    • SiC
    • FRD(MUR)
    • Bridge Rectifier
  • Application 
    • Electric Vehicle
    • Home Appliance
    • Renewable Energy
    • Industrial Control
    • Electric Power Supplys
  • Technology 
    • Latest IPM Technology
    • High Voltage (HV) Die Technolog
    • Reliability & Qualification
  • About Us 
    • Our Company
    • Technical Team
    • Custom Solutions
  • Contact Us
  • Blog
  • …  
    • Home
    • Products 
      • IPM by Package
      • IGBT Modules
      • IGBT Discretes
      • IGBT Chips
      • SiC
      • FRD(MUR)
      • Bridge Rectifier
    • Application 
      • Electric Vehicle
      • Home Appliance
      • Renewable Energy
      • Industrial Control
      • Electric Power Supplys
    • Technology 
      • Latest IPM Technology
      • High Voltage (HV) Die Technolog
      • Reliability & Qualification
    • About Us 
      • Our Company
      • Technical Team
      • Custom Solutions
    • Contact Us
    • Blog
Free Sample
We design and manufacture semiconductor chips, discrete power devices, and power modules for your products.

What Is JEDEC Reliability Testing? JESD22 Standards and When They Are Enough

Introduction: “tested to JEDEC” — tested to which clause?

“We have a JEDEC report. Why won’t the customer accept it?”

“Because JEDEC isn’t a standard, it’s a family,” Dave said. “Saying ‘we tested to JEDEC’ is like saying ‘we cooked to the national code.’ There are thousands of dishes in there. Which one?”

JESD22 is the most widely used reliability method set in the industry. Nearly every lab can run it and nearly every customer has heard of it. But precisely because it is general, reports often stay vague: conditions self-selected, criteria self-defined, sample size self-chosen — producing a document anyone can sign and nobody should trust.

Here is what JESD22 actually contains, where it genuinely differs from AEC-Q101, and when “JEDEC is enough.”

Who JEDEC is, and what JESD22 governs

JEDEC (Solid State Technology Association) is the industry’s standards body, with members across device makers, equipment vendors, OEMs and labs. Its publications split into quality and reliability (JESD22, JESD47), packaging and outlines (JESD30, MO series), and test methods.

JESD22 is the environmental and lifetime test method family: it defines how to apply a stress, for how long, and how to judge the result — not what level a device must reach. That distinction matters: JESD22 is a method standard, and pass/fail is agreed between supplier and customer.

JESD47 (stress-test-driven qualification of ICs) supplies the qualification logic around it. For power devices, JESD22 plus a JESD47 mindset covers most needs.

Seven part numbers worth memorizing

StandardTitleTypical conditionsPrimary useJESD22-A108Temperature, bias and operating life (HTOL / HTRB)Tj max, rated voltage, 1,000 hLong-term blocking and operating life; the core power device testJESD22-A101Steady state temperature humidity bias life (THB)85°C/85%RH, rated voltage, 1,000 hCorrosion and insulation reliability in humid environmentsJESD22-A110Highly accelerated stress test (HAST)130°C/85%RH, biased, 96 hAccelerated THB substitute for development phasesJESD22-A104Temperature cycling-65 to +150°C, 500–1,000 cyclesPackage interface thermal fatigueJESD22-B103Vibration, variable frequency20–2,000 Hz, 20 G peakTransport and operating vibrationJESD22-B104Mechanical shock1,500 G, 0.5 ms pulseDrop and impact eventsJESD22-B106Resistance to soldering temperatureReflow / wave solder thermal shockPackage tolerance of the soldering process

One correction that keeps appearing in Chinese-language material: mechanical shock is JESD22-B104, not B106. B106 is resistance to soldering temperature. One is a mechanical impact, the other a soldering thermal shock. Wrong part numbers are an easy way to lose credibility.

The real gap between JEDEC and AEC-Q101

It is not simply “loose versus strict.” They differ on four dimensions, and the fourth is the expensive one.

DimensionJEDEC JESD22AEC-Q101ConditionsRange given; agreed by the partiesLargely fixed (e.g. TC -55 to +150°C, 1,000 cycles)Sample sizeAs agreed, commonly 25–45 per lot77 per lot with zero failures for most testsCriteriaNegotiable, usually relative driftUnified relative plus absolute limitsChange controlGenerally not mandatedStrict; PCN notification and re-evaluation requiredReport formatSupplier-definedAligned with automotive customers, lot and FA records included

That fourth row explains the real cost. What makes AEC-Q101 expensive is not the test fee but change control: once a part number is qualified, a new supplier or material restarts the process. That hidden cost is often several times the testing itself. JEDEC has no such constraint — which is exactly why automotive customers cannot accept it directly.

Why 96 hours of HAST can stand in for 1,000 hours of THB

THB is unbiased-pressure 85°C/85%RH with bias, run for 1,000 hours. HAST puts parts in a pressurized vessel at 130°C/85%RH (unsaturated steam) with bias, for 96 hours. Higher temperature and higher water vapour pressure accelerate moisture ingress and electrochemical corrosion, compressing time by roughly ten times.

But “equivalent” has three preconditions:

  • The mechanism must be the same — moisture-driven corrosion and migration, not the molding compound softening first.
  • It applies to non-hermetic packages — hermetic ceramic or metal packages do not absorb moisture, so HAST adds little.
  • HAST is a screen, not a lifetime model — 96 hours exposes seal defects quickly, but quantitative life extrapolation still needs THB or longer data.

Practical rule: HAST for fast iteration during development, THB for the formal qualification conclusion. Running both costs little extra and changes how much the report is worth.

Flexibility is the feature and the trap

JESD22 leaves conditions to the parties so the standard can fit many applications. In real projects that turns into three common shortcuts:

  1. Conditions taken at the low end. TC at -40 to +125°C for 500 cycles, reported as “passed JESD22-A104.” Technically true, but the customer assumes -65 to +150°C for 1,000.
  2. Sample size cut. 25 parts and 77 parts differ by an order of magnitude in statistical meaning, yet both say “per JESD22.”
  3. Criteria relaxed silently. No drift limit, only “functionally OK” — which is no criterion at all.

So when reading a JEDEC report, ignore the standard number on the cover and check four things: conditions, sample size, read points, criteria. With all four, the report is comparable. Without them, it is an internal record.

When JEDEC is enough — and when it is not

ApplicationSufficient?RecommendationConsumer power, fast chargers, appliancesYesBaseline JESD22 plus customer-specified tighteningIndustrial power, drives, UPSMostlyJESD22 plus H3TRB and extended TC; some customers ask for AEC-like conditionsPV inverters, energy storageNeeds tighteningJESD22 baseline plus IOL power cycling and H3TRB, swings sized to outdoor dutyAutomotive (charging, OBC, traction)NoAEC-Q101 required (modules: Q104 / AQG 324); JEDEC is method reference onlyMilitary, aerospaceNoMIL-STD-883 plus program specs, including 100% screening and radiation

One-line principle: JEDEC decides whether you know how to test; AEC decides whether anyone accepts the answer. For industrial products, solid JEDEC work is enough. For automotive, JEDEC is your internal skill — AEC is the coat you wear in public.

FAQ

How does JESD22-A104 differ from the AEC-Q101 TC?

Same method family, different conditions. AEC-Q101 TC typically requires -55 to +150°C for 1,000 cycles with defined transfer times; A104 gives a range (e.g. -65 to +150°C, 500–1,000 cycles) agreed by the parties. Passing A104 is not the same as passing Q101 TC.

Can HAST fully replace THB?

Not fully. HAST is a fast screen for seal and moisture defects; THB is longer and closer to real storage and operating conditions, making it better suited to a qualification conclusion. Many customers accept either, or specify HAST conditions explicitly.

What if a customer rejects a JEDEC report?

First establish whether they need the method or the conclusion. If only the method, a cross-reference table showing your conditions cover the AEC items may suffice. If they need the conclusion, re-report the same test data against AEC-Q101 criteria — one campaign, two reports.

What are JESD22-B104 and B106?

B104 is mechanical shock (typically 1,500 G, 0.5 ms). B106 is resistance to soldering temperature, which evaluates the package against reflow or wave solder thermal shock. The two are frequently confused in secondary sources.

Subscribe
Previous
What Is AEC-Q101? Eight Tests, 77 Samples, and Three...
 Return to site
feed icon
Profile picture
Cancel
Cookie Use
We use cookies to improve browsing experience, security, and data collection. By accepting, you agree to the use of cookies for advertising and analytics. You can change your cookie settings at any time. Learn More
Accept all
Settings
Decline All
Cookie Settings
These cookies enable core functionality such as security, network management, and accessibility. These cookies can’t be switched off.
These cookies help us better understand how visitors interact with our website and help us discover errors.
These cookies allow the website to remember choices you've made to provide enhanced functionality and personalization.
Save